ACSR CABLE(Aluminum conductor steel reinforced)

ACSR CABLE(Aluminum conductor steel reinforced)
Product Detailed
ACSR 1. Low price ,Best Quality 2. Fast delivery 3.OEM order taken 4. All required standard

1.Standard 

Bare Aluminum ConductorAll aluminum Stranded Conductor (AAC)Aluminum Stranded Conductor Steel Reinforced (ACSR)Aluminum Alloy Stranded Conductor(Steel reinforced) (AAAC,AACSR)Copper Clad Aluminum Wire (CCA)Rare Aluminum Stranded ConductorRare Aluminum Stranded Conductor Steel Reinforced.

Used in the electricity transmission lines, with high voltage and large span.From tower to tower.Low cost and good performance makes its iomportant position in the Electricity transmission.

Rare product serious are used in moist coast areas for the good properties of conductivity,anti-corrosion and acid-resistance.

Zinc-Coating Availible.

2.Applications

1.ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country.It  especially suit the transmission of electric power of high and very high voltages, having large span runs.

2.The ACSR wires that added in lanthanon (rare-earth metal) are used in moist coaseal areas for their good properties of conductivity,anti-corrosion and acid-resistance.

3.Specifications Table

Model

ACSR85mm

Similar to the ASTM-B232 Code word

Pigeon

Cross-section Area of the Conductor (mm²)

Alumunim wire

85.03mm²

Steel wire

14.19mm²

No. and Dia. Of the Wires

Aluminum wire

6/4.25mm

Steel wire

1/4.25mm

Overall Dia. Of the Conductor (mm)

12.75mm

Max. D.C. Resistance (Ω/km)

0.3373Ω/km

Breaking Load (N)

2941 daN

Weight (kg/km)

343 kg/km   2.9km/MTon

4.Using Properties

1. Max. permission operating temperature shall be not exceed 80°C

2.Building Temperature shall not below -20°C

3.The laying bending radius shall not be less than 12 times the outer diameter of the cable.

5.Cross-section Drawing

We and Our group...

-------------------------------------------------------------------------------------------------------------------------------

SizeStranding designStrandingNominalO.D.Mass
Aluminum wiresteel wire
NumberdiameterlayersNumberdiameterlayers
mm²  mm  mm mmkg/km
          
          
          
          
          
          
          
          
50054/7543.43373.43130.871889
50045/7453.76372.51130.091656
45054/7543.26373.26129.341706
45045/7453.57372.38128.561492
          
40030/19304.122192.47228.831824
40026/7264.43273.45128.071622
40024/7244.61273.07127.651515
35530/19303.882192.33227.171620
35526/7264.17273.24126.41435
35524/7244.34272.89126.031343
          
31530/19303.662192.2225.641443
31526/7263.93273.06124.91277
31524/7244.09272.73124.551194
31518/1184.72214.72023.61014
          
28030/7303.45273.45124.151291
28026/7263.7272.88123.441131
28024/7243.85272.57123.111058
28018/1184.45214.45022.25901
          
25030/7303.26273.26122.821152
25026/7263.5272.72122.161011
25024/7243.64272.43121.85946
25018/1184.21214.21021.05806.4
          
22430/7303.08273.08121.561029
22426/7263.31272.57120.95904
22424/7243.45272.3120.7849.2
22418/1183.98213.98019.9720.7
          
20030/7302.91272.91120.37918.2
20026/7263.13272.43119.81808.3
20024/7243.26272.17119.55757.6
20018/1183.76213.76018.8643.2
          
18030/7302.76272.76119.32826
18026/7262.97272.31118.81728.6
18024/7243.09272.06118.54681.2
18018/1183.57213.57017.85579.9
          
16030/7302.61272.61118.27738.6
16026/7262.8272.18117.74648
16024/7242.91271.94117.46604.2
16018/1183.36213.36016.8513.7
14026/7262.62272.04116.6567.4
14024/7242.73271.82116.38531.8
14018/1183.15213.15015.75451.5
12526/7262.47271.92115.64503.7
12524/7242.58271.72115.48474.9
12518/1182.97212.97014.85401.3
          
10016/19162.821192.44217.84972.4
10012/7123.26173.26116.3734.1
1006/164.61114.61013.83404.8
9012/7123.09173.09115.45659.5
          
8012/7122.91172.91114.55584.9
806/164.12114.12012.36323.3
7112/7122.74172.74113.7518.6
6312/7122.59172.59112.95463.4
636/163.66113.66010.98255.2
5612/7122.44172.44112.2411.2
          
5012/7122.3172.3111.5365.4
506/163.26113.2609.78202.4
408/182.52114.209.24217.9
406/162.91112.9108.73161.3
          
31.57/172.39113.1907.97148.4
31.56/162.59112.5907.77127.8
257/172.13112.8407.1117.8
256/162.3112.306.9100.8
          
207/171.91112.5506.3794.8
206/162.06112.0606.1880.83
166/161.84111.8405.5264.49
12.56/161.63111.6304.8950.61

PVC insulatd electrical wire, hoop-up wire, and Control cable / wire

These are bare conductors ACSR, AAC,and AAAC etc. and ABC Cable

Power Cable

And dear buyers, we are able to take OEM orders. So if you are a project dealer or a supplier and there is a special designation,Kindly let we know, it will be solved in the best ways.

Contact me:

Achi Wan (Mr.)

skype: achiwan



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.